Page 27 - RM_2022
P. 27
02 Low pressure equipment
Descaling pumps and softening agents
ST-15 descaling softening pumps Softening agents
This product bounds
the minerals causing
4 60 4 60
the hardness. The coil
is protected against
calcination.
132 122 132 122
Application:
4 ml / °dH / cbm water.
1 palett = 84 cardboard
boxes (6 x 1 l)
72 72
For trailer mounted pressure washers
R+M Nr. hp cleaner R+M Nr. hp cleaner R+M Nr. unit
200 015 500 < 600 l/h 230 V - 50 Hz 35 200 015 526 > 900 l/h 12 V = 140 950 10 box 6 x 1 l
200 015 510 < 600 l/h 24 V - 50 Hz 35 950 40 container 10 l
200 015 505 > 600 l/h 230 V - 50 Hz 70 950 50 container 20 l
200 015 535 > 900 l/h 230 V - 50 Hz 140 950 20 drum 200 l
200 015 525 > 900 l/h 24 V - 50 Hz 140
Low pressure valves
Check valves & intake filter
R+M check valve. Valve nylon with rubber seal. Intake filter.
Stainless steel spring. Avoids backflow in any Nylon thread.
position Stainless steel mesh
R+M Nr. R+M Nr.
3/8" 733 004 44 mm 16 bar 732 80 18 mm 42 mm
1/2" 733 054 48 mm 16 bar 732 70 22 mm 38 mm
3/4" 733 104 53 mm 16 bar 732 60 28 mm 50 mm
1" 733 204 58 mm 16 bar 732 90 36 mm 57 mm
1.1/4" 733 304 66 mm 10 bar 732 95 43 mm 65 mm
Backflow preventers
Chrome-plated brass. Backflow pre-
Endangerment of drinking water
venter according to DIN 19884 and
DIN EN 1717. Avoids that cleaning It is a TYPE HD pipe aerator, which completely covers the risk in category 1 and 2, and only
agents come into the potable drink partially in category 3. Not permitted for categories 4 and 5.
circuit in case of excess pressure Use is only intended for private use.
in the water pipe. Required when
Type of hazard according to DIN EN 1717 (DIN 1988-4)
direct connection to pump
category 1 category 2 category 3 category 4 category 5
Industrial or Liquid without Liquid, with a Liquid with a Liquid with a
drinking water, health risk, but health hazard strong health life-threatening
without any with adverse due to low toxic hazard. Toxic, risk from
health risk or effects (smell, substances (glycol, carcinogenic, microbial
R+M Nr. impairment taste, color, caustic soda, mutagenic or or viral
(smell, taste, color) temperature) copper sulfate radioactive pathogens.
734 10 3/4" 20 61 mm
solution ...) substances.
According to the EU directives EN 60335-2-79:2010 currently in force, the water that passes through a high pressure cleaner is no
longer considered fit for drinking. This is why such a cleaner cannot be connected directly to the drinking water supply network
unless a back flow preventer disconnector has been fitted.