Page 104 - BVA_2022
P. 104

Maintaining Your Equipment                                                                                                                                                                  Alphabetical Index

          Ensure a longer life span of your equipment

          Hydraulic Fluids
          •  Use only BVA Hydraulic Oil P/N’s; HV155 or HV685 for pumps and cylinders.                                                 A                              CVP               68               J
                                                                                                                                     AMP              80              CVS              72              J                 93
                                                                                                                                     AP                82 + 89        CT                  90
          Air Line Lubricants
          •  Use Class 1 Turbine Oil (ISO VG32) for Air Line Lubricant                                                               APC              84              CVR              68                L
                                                                                                                                     APE              86 - 87                                          LH                44

          Hydraulic and Pneumatic Filtration                                                                                         APH              77 - 83           F
          •  Hydraulic fluid must be kept clean, cool and free of water.                                                             APHC             79 - 85 + 89    FP                72               M
          •  Use Hydraulic Filtration to provide fluid which meets ISO 17/15/12 cleanliness levels.                                  API               81 - 87         FT               77             MFC              70
          •  Air Line Filtration for solid particulate contamination removal: Use BVA P/N; FRL-145, 5uM Pneumatic Filter.
          •  Air Line Water Removal; Use BVA P/N; AD-145, Ambient Dryer.                                                             APK              83 + 85
                                                                                                                                     APL              82 - 84           G                                N

          Proper Operation of Equipment                                                                                              APLC              78 - 84        GBW              71              NS                92
          •  Refer to individual Product Owner’s Manuals and BVA Catalogs for general information, specifications,                   APP              80 - 86         GD                71             NSB              92
             safety, set up, operation, maintenance, trouble shooting, storage and warnings for all BVA products.                    APS              81 - 83 + 87    GSW              71
                                                                                                                                                                                                         P
                                                                                                                                       B                                H                              P                 44 - 47
                                                                                                                                     BVA Bag         92               H                 6 - 9          PA                47 - 49
          Formulas                                                                                                                                                    HC                  30 - 31      PUAR             54

                                                                                                                                       C                              HD                10 - 13        PUARD          50
                                                      Cylinder Plunger Speed                                                         CA                77             HDC              32 - 33         PD                62 - 63
                            Key to
                                                                    A
                         Measurements                   Formula   →   V =      × 60                                                  CB                45 + 77        HDG              26 - 39         PE                56 - 59
                                                                    Q
                                                                                  Cylinder Effective Area (cm )      60 (sec)
                                                                                                   2
                                                                                                    ×
                                                          Cylinder Plunger Speed (sec/cm )  =     Pump Flow Rate (cm /min)           1 (min)  CDC              72     HDU              36 - 37         PFC              74
                                                                              2
                                                                                               3
                  Weight:              Length
                                                                                                                                     CEB              44              HF                16 - 17        PG               62 - 63
                                                      Force                                                                          CEBN / CED  43                   HFS              91              PPC              74
            1 pound (lb.)  =0.4536 kg  1 in  =25.4 mm
                                                        Formula   →   F = P × A                                                      CEFN / CEN  43                   HFSS             91              PR                75
                                                                                         2
                                                          Force (kg )  =  Hydraulic Working Pressure (kg/cm ) × Cylinder Effective Area (cm ) 2  CEP              44  HG                22 - 25        PU                55
              1 kg     =2.205 lbs  1 mm    =0.039 in
                                                                                                                                     CF                71             HGPT             88              PUW              76
             1 Tonne
           (short ton, US)  =2,000 lbs  1 in²  =6.452 cm²  Cylinder Oil Capacity                                                     CH                73             HL                14 - 15        PWS              74
                                                                                                                                     CM                70             HLN              18 - 19         PW                 72
             1 Tonne                                    Formula   →   C = A × L
             (metric)  =2,205 lbs  1 cm²   =0.155 in²     Oil Capacity (cm ) =  Cylinder Effective Area (cm ) × Cylinder Stroke (cm)  CMH              70             HLNF             20 - 21
                                                                                        2
                                                                    3
                                                                                                                                     CMRU              74             HP                42               S
                 Volume:             Pressure:
                                                                                                                                     CP                42             HPB              42              SA                64 - 65
                                                      ¼” Hose Oil Capacity                                                           CQ                73             HPD              43 - 44         SD                45
              1 in³   =16.387 cm³  1 psi (lb/in²)  =0.69 bar        Internal Diameter (mm )
                                                                                  2
                                                        Formula   →   C =                                             ×        ×  Length of Hose (m)   CQF              73  HT               41        SDT              45
                                                                              4
                                                                    3
                                                          Oil Capacity (cm ) =  33 × Length of Hose (m)                              CQH               76             HTD              34 - 35         SDTG             45
              1 cm³    =0.061 in³  1 bar   =14.5 psi
                                                                                                                                     CQR              73              HU                34 - 35        SDTL              45
                       =61.02 in³  1 kPa   =0.145 psi  ⅜” Hose Oil Capacity                                                          CR                73             HUC               39             SEC               79
              1 liter                                               Internal Diameter (mm )                                          CS                73             HUDC            40               SED               79
                                                                                  2
                                                        Formula   →   C =                                             ×        ×  Length of Hose (m)
                                                                              4
                     =0.264 gal(US)                                                                                                  CSH               67             HULN             38              SMS               78
                                                                    3
                                                          Oil Capacity (cm ) =  72 × Length of Hose (m)
                                                                                                                                     CVC              69              HV                72             SP                64 - 65
                       =3.785 liter  Temperature:                                                                                    CVL              69              HVSP             90              SR                91
                                                      Cylinder Effective Area
                                                                       D 2                                                           CVLS             69
                                                        Formula   →   A =   ×
          1 gal (US, liquid)  =231 in³  0°F  =(0°C x 1.8) + 32         4                     2
                                                          Cylinder Effective Area  =   ×  (Cylinder Bore Diameter)                   CVN              68                                                 T
                                                                                     4
                                                                                                                                                                                                       TB                  66 - 67
                       =3,785 cm³  0°C   =(0°F - 32) ÷ 1.8
                                                              = 3.14159265359
                                                                                                                                © Copyright 2022 SFEU Companies
                                                                                                                                All rights reserved. Any copying or other use of the material in this catalog (text, illustrations, drawings, photos) without
    104                                                                                                                         prior express written consent is prohibited. Information in this catalog is subject to change without prior notice.   105
    104
   99   100   101   102   103   104   105   106   107   108